Tank Storage Heating in Oxelösund
Tank Storage Heating in Oxelösund
Client: Peab Asfalt AB
Period: 2023
Delivery: Temperature maintenance for bitumen storage
Application Areas: Industrial – Tank Heating
The challenge
The existing tanks at Peab Asfalt’s facility in Oxelösund were equipped with heating systems that experienced issues with coking. For bitumen, coking is typically caused not by the tank temperature itself, but by the surface temperature of the heating elements. Proxll has developed a heating solution designed with a low surface load specifically to prevent coking.
The solution
Peab Asfalt AB chose Proxll to replace the existing heating system at its facility in Oxelösund.
Proxll supplied a complete electric heating system for three existing bitumen tanks, including engineering and design, manufacturing, delivery, installation, testing and commissioning. The solution was developed by Proxll for the storage of bitumen at 160–170 °C under Nordic climate conditions.
Scope of delivery included:
- Engineering and thermal design of the system
- Supply of specially developed steatite-based heating elements (cartridges) for high operating temperatures, including junction boxes.
- Temperature sensors and safety equipment
- Documentation, testing and final inspection
- On-site installation and commissioning support
The result
Proxll’s solution for Peab Asfalt’s bitumen tanks in Oxelösund ensures stable bitumen storage throughout the year without coking. Coking with conventional heating elements occurs when local surface temperatures become too high. Proxll therefore uses specially developed heating elements with a low surface load and even heat distribution, reducing the risk of product degradation and coke formation, even during continuous operation.
By replacing the existing heating elements with Proxll’s steatite-based heating elements, Peab has gained a robust and durable solution that provides:
✓ Increased operational reliability – Ensures stable asphalt production.
✓ Improved monitoring – The control system provides alarms and early warnings in the event of faults or potential hazards.
✓ Lower maintenance costs – The heating system is virtually maintenance-free.
✓ Energy-efficient operation – Optimized energy consumption based on actual heating requirements at low outdoor temperatures.
With Proxll’s specially developed tank heating solution, Peab Asfalt has resolved the challenges associated with coking on the heating elements. The solution provides a low surface load, stable temperature control and increased operational reliability for the bitumen tanks.